False-Positive Mycobacterium tuberculosis Cultures in 44 Laboratories in The Netherlands (1993 to 2000): Incidence, Risk Factors, and Consequences

ABSTRACT False-positive Mycobacterium tuberculosis cultures are a benchmark for the quality of laboratory processes and patient care. We studied the incidence of false-positive cultures, risk factors, and consequences for patients during the period from 1993 to 2000 in 44 peripheral laboratories in The Netherlands. The national reference laboratory tested 8,889 M. tuberculosis isolates submitted by these laboratories. By definition, a culture was false positive (i) if the DNA fingerprint of the isolate was identical to that of an isolate from another patient processed within 7 days in the same... Mehr ...

Verfasser: de Boer, Annette S.
Blommerde, Barbara
de Haas, Petra E. W.
Sebek, Maruschka M. G. G.
Lambregts-van Weezenbeek, Kitty S. B.
Dessens, Mirjam
van Soolingen, Dick
Dokumenttyp: Artikel
Erscheinungsdatum: 2002
Reihe/Periodikum: Journal of Clinical Microbiology ; volume 40, issue 11, page 4004-4009 ; ISSN 0095-1137 1098-660X
Verlag/Hrsg.: American Society for Microbiology
Sprache: Englisch
Permalink: https://search.fid-benelux.de/Record/base-29166744
Datenquelle: BASE; Originalkatalog
Powered By: BASE
Link(s) : http://dx.doi.org/10.1128/jcm.40.11.4004-4009.2002

ABSTRACT False-positive Mycobacterium tuberculosis cultures are a benchmark for the quality of laboratory processes and patient care. We studied the incidence of false-positive cultures, risk factors, and consequences for patients during the period from 1993 to 2000 in 44 peripheral laboratories in The Netherlands. The national reference laboratory tested 8,889 M. tuberculosis isolates submitted by these laboratories. By definition, a culture was false positive (i) if the DNA fingerprint of the isolate was identical to that of an isolate from another patient processed within 7 days in the same laboratory, (ii) if the isolate was taken from a patient without clinical signs of tuberculosis, and/or (iii) if the false-positive test result was confirmed by the peripheral laboratory and/or the public health tuberculosis officer. We identified 213 false-positive cultures (2.4%). The overall incidence of false-positive cultures decreased over the years, from 3.9% in 1993 to 1.1% in 2000. Laboratories with false-positive cultures more often processed less than 3,000 samples per year ( P < 0.05). Among 110 patients for whom a false-positive culture was identified from 1995 to 1999, we found that for 36% of the patients an official tuberculosis notification had been provided to the appropriate public health services, 31% of the patients were treated, 14% of the patients were hospitalized, and a contact investigation had been initiated for 16% of the patients. The application of DNA fingerprinting to identify false-positive M. tuberculosis cultures and the provision of feedback to peripheral laboratories are useful instruments to improve the quality of laboratory processes and the quality of medical care.