Assessment of ICD eligibility in non-ischaemic cardiomyopathy patients:a position statement by the Task Force of the Dutch Society of Cardiology

International guidelines recommend implantation of an implantable cardioverter-defibrillator (ICD) in non-ischaemic cardiomyopathy (NICM) patients with a left ventricular ejection fraction (LVEF) below 35% despite optimal medical therapy and a life expectancy of more than 1 year with good functional status. We propose refinement of these recommendations in patients with NICM, with careful consideration of additional risk parameters for both arrhythmic and non-arrhythmic death. These additional parameters include late gadolinium enhancement on cardiac magnetic resonance imaging and genetic test... Mehr ...

Verfasser: van der Lingen, Anne-Lotte C. J.
Verstraelen, Tom E.
van Erven, Lieselot
Meeder, Joan G.
Theuns, Dominic A.
Vernooy, Kevin
Wilde, Arthur A. M.
Maass, Alexander H.
Allaart, Cornelis P.
Dokumenttyp: Artikel
Erscheinungsdatum: 2024
Reihe/Periodikum: van der Lingen , A-L C J , Verstraelen , T E , van Erven , L , Meeder , J G , Theuns , D A , Vernooy , K , Wilde , A A M , Maass , A H & Allaart , C P 2024 , ' Assessment of ICD eligibility in non-ischaemic cardiomyopathy patients : a position statement by the Task Force of the Dutch Society of Cardiology ' , Netherlands Heart Journal , vol. 32 , no. 5 , pp. 190-197 . https://doi.org/10.1007/s12471-024-01859-7
Schlagwörter: Non-ischaemic cardiomyopathy / Implantable cardioverter defibrillator / Mortality / Sudden cardiac death / IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR / PRIMARY PREVENTION / HEART-FAILURE / DILATED CARDIOMYOPATHY / VENTRICULAR-ARRHYTHMIAS / RISK STRATIFICATION / MUTATION CARRIERS / EUROPEAN-SOCIETY
Sprache: Englisch
Permalink: https://search.fid-benelux.de/Record/base-29021645
Datenquelle: BASE; Originalkatalog
Powered By: BASE
Link(s) : https://cris.maastrichtuniversity.nl/en/publications/f56b408c-d772-44d7-8c0f-9ae8a2288c88