KENYAMANAN TERMAL PADA BANGUNAN KOLONIAL BELANDA DI SEMARANG

Dutch colonial building in Semarang categorized in three groups; buildings built without considering the humid-tropical climate, those in which a part of the building was adapted and whole buildings built suitable for the humid-tropical climate. From third the category tested with measuring air temperature, humidity and air movement in building to be processed by using PMV ( Predicted Mean Vote) according to P.O. Fanger. From result of this research can know, which ist the part of building, which have important role and how big its role in improving the building comfort. Abstract in Bahasa Ind... Mehr ...