Everolimus-eluting bioresorbable scaffolds and metallic stents in diabetic patients: a patient-level pooled analysis of the prospective ABSORB DM Benelux Study, TWENTE and DUTCH PEERS

Abstract Background Several studies compared everolimus-eluting bioresorbable scaffolds (EE-BRS) with everolimus-eluting stents (EES), but only few assessed these devices in patients with diabetes mellitus. Aim To evaluate the safety and efficacy outcomes of all-comer patients with diabetes mellitus up to 2 years after treatment with EE-BRS or EES. Methods We performed a post hoc pooled analysis of patient-level data in diabetic patients who were treated with EE-BRS or EES in 3 prospective clinical trials: The ABSORB DM Benelux Study (NTR5447), TWENTE (NTR1256/NCT01066650) and DUTCH PEERS (NTR... Mehr ...

Verfasser: T. M. Hommels
R. S. Hermanides
B. Berta
E. Fabris
G. De Luca
E. H. Ploumen
C. von Birgelen
E. Kedhi
Dokumenttyp: Artikel
Erscheinungsdatum: 2020
Reihe/Periodikum: Cardiovascular Diabetology, Vol 19, Iss 1, Pp 1-10 (2020)
Verlag/Hrsg.: BMC
Schlagwörter: Bioresorbable scaffolds / Drug-eluting stents / Diabetes mellitus / Coronary artery disease / Percutaneous coronary intervention / Device thrombosis / Diseases of the circulatory (Cardiovascular) system / RC666-701
Sprache: Englisch
Permalink: https://search.fid-benelux.de/Record/base-28985035
Datenquelle: BASE; Originalkatalog
Powered By: BASE
Link(s) : https://doi.org/10.1186/s12933-020-01116-2

Abstract Background Several studies compared everolimus-eluting bioresorbable scaffolds (EE-BRS) with everolimus-eluting stents (EES), but only few assessed these devices in patients with diabetes mellitus. Aim To evaluate the safety and efficacy outcomes of all-comer patients with diabetes mellitus up to 2 years after treatment with EE-BRS or EES. Methods We performed a post hoc pooled analysis of patient-level data in diabetic patients who were treated with EE-BRS or EES in 3 prospective clinical trials: The ABSORB DM Benelux Study (NTR5447), TWENTE (NTR1256/NCT01066650) and DUTCH PEERS (NTR2413/NCT01331707). Primary endpoint of the analysis was target lesion failure (TLF): a composite of cardiac death, target vessel myocardial infarction or clinically driven target lesion revascularization. Secondary endpoints included major adverse cardiac events (MACE): a composite of all-cause death, any myocardial infarction or clinically driven target vessel revascularization, as well as definite or probable device thrombosis (ST). Results A total of 499 diabetic patients were assessed, of whom 150 received EE-BRS and 249 received EES. Total available follow-up was 222.6 patient years (PY) in the EE-BRS and 464.9 PY in the EES group. The adverse events rates were similar in both treatment groups for TLF (7.2 vs. 5.2 events per 100 PY, p = 0.39; adjusted hazard ratio (HR) = 1.48 (95% confidence interval (CI): 0.77–2.87), p = 0.24), MACE (9.1 vs. 8.3 per 100 PY, p = 0.83; adjusted HR = 1.23 (95% CI: 0.70–2.17), p = 0.47), and ST (0.9 vs. 0.6 per 100 PY, p > 0.99). Conclusion In this patient-level pooled analysis of patients with diabetes mellitus from 3 clinical trials, EE-BRS showed clinical outcomes that were quite similar to EES.