Robustness analysis of CTV and OAR dose in clinical PBS-PT of neuro-oncological tumors: prescription-dose calibration and inter-patient variation with the Dutch proton robustness evaluation protocol

Abstract Objective . The Dutch proton robustness evaluation protocol prescribes the dose of the clinical target volume (CTV) to the voxel-wise minimum (VWmin) dose of 28 scenarios. This results in a consistent but conservative near-minimum CTV dose (D 98%,CTV ). In this study, we analyzed (i) the correlation between VWmin/voxel-wise maximum (VWmax) metrics and actually delivered dose to the CTV and organs at risk (OARs) under the impact of treatment errors, and (ii) the performance of the protocol before and after its calibration with adequate prescription-dose levels. Approach . Twenty-one ne... Mehr ...

Verfasser: Rojo-Santiago, Jesús
Habraken, Steven J M
Romero, Alejandra Méndez
Lathouwers, Danny
Wang, Yibing
Perkó, Zoltán
Hoogeman, Mischa S
Dokumenttyp: Artikel
Erscheinungsdatum: 2023
Reihe/Periodikum: Physics in Medicine & Biology ; volume 68, issue 17, page 175029 ; ISSN 0031-9155 1361-6560
Verlag/Hrsg.: IOP Publishing
Sprache: unknown
Permalink: https://search.fid-benelux.de/Record/base-28600049
Datenquelle: BASE; Originalkatalog
Powered By: BASE
Link(s) : http://dx.doi.org/10.1088/1361-6560/acead1