Towards Energy Efficient Onsite Wastewater Treatment

The objective of this work is to demonstrate that some weaknesses of the onsite packaged WWTP associated with high operational costs and energy inefficiency could be overcome by improved management. The research methodology consists of series of batch studies with sludge from municipal or onsite WWTP, which simulate different working regimes of the onsite WWTPs – daily operation, toilet flushing and dishwasher machine. A simple classical tool, Oxygen Uptake Rate (OUR) is used to prove the hypothesis that regardless the specificity of the onsite WWTPs, namely the irregularity of the flow and lo... Mehr ...

Verfasser: Irina Ribarova
Christian Ribarov
Renata Mirra
Dobril Valchev
Dokumenttyp: Artikel
Erscheinungsdatum: 2020
Schlagwörter: Netherlands / Aurora Universities Network / Energy Research / Geotechnical Engineering and Engineering Geology / Building and Construction / Civil and Structural Engineering / Environmental Engineering