Resultados de los stents Resolute Integrity y Promus Element en el infarto de miocardio:análisis del ensayo aleatorizado DUTCH PEERS (TWENTE II) ; Outcome After Myocardial Infarction Treated With Resolute Integrity and Promus Element Stents:Insights From the DUTCH PEERS (TWENTE II) Randomized Trial

Introduction and objectives In acute myocardial infarction (MI), novel highly deliverable drug-eluting stents (DES) may be particularly valuable as their flexible stent designs might reduce device-induced traumas to culprit lesions. The aim of the study was to assess the safety and efficacy of percutaneous coronary interventions with 2 novel durable polymer-coated DES in patients with acute MI. Methods The prospective, randomized DUTCH PEERS (TWENTE II) multicenter trial compares Resolute Integrity and Promus Element stents in 1811 all-comer patients, of whom 817 (45.1%) were treated for ST-se... Mehr ...

Verfasser: van Houwelingen, K. Gert
Lam, Ming Kai
Löwik, Marije M.
Danse, Peter W.
Tjon Joe Gin, R. Melvyn
Jessurun, Gillian A.
Anthonio, Rutger L.
Sen, Hanim
Linssen, Gerard C.M.
IJzerman, Maarten J.
Doggen, Carine J.M.
von Birgelen, Clemens
Dokumenttyp: Artikel
Erscheinungsdatum: 2016
Reihe/Periodikum: van Houwelingen , K G , Lam , M K , Löwik , M M , Danse , P W , Tjon Joe Gin , R M , Jessurun , G A , Anthonio , R L , Sen , H , Linssen , G C M , IJzerman , M J , Doggen , C J M & von Birgelen , C 2016 , ' Resultados de los stents Resolute Integrity y Promus Element en el infarto de miocardio : análisis del ensayo aleatorizado DUTCH PEERS (TWENTE II) ' , Revista Espanola de Cardiologia , vol. 69 , no. 12 , pp. 1152-1159 . https://doi.org/10.1016/j.recesp.2016.05.033
Sprache: Spanish
Permalink: https://search.fid-benelux.de/Record/base-27071987
Datenquelle: BASE; Originalkatalog
Powered By: BASE
Link(s) : https://pure.eur.nl/en/publications/395daef0-cde2-4323-8ab0-e18f41e9bc9e

Introduction and objectives In acute myocardial infarction (MI), novel highly deliverable drug-eluting stents (DES) may be particularly valuable as their flexible stent designs might reduce device-induced traumas to culprit lesions. The aim of the study was to assess the safety and efficacy of percutaneous coronary interventions with 2 novel durable polymer-coated DES in patients with acute MI. Methods The prospective, randomized DUTCH PEERS (TWENTE II) multicenter trial compares Resolute Integrity and Promus Element stents in 1811 all-comer patients, of whom 817 (45.1%) were treated for ST-segment elevation MI or non—ST-segment elevation MI and the 2-year outcome is available in 99.9%. The primary clinical endpoint is target vessel failure (TVF), a composite of cardiac death, target vessel related MI, or target vessel revascularization. Results Of all 817 patients treated for acute MI, 421 (51.5%) were treated with Resolute Integrity and 396 (48.5%) with Promus Element stents. At the 2-year follow-up, the rates of TVF (7.4% vs 6.1%; P =.45), target lesion revascularization (3.1% vs 2.8%; P =.79), and definite stent thrombosis (1.0% vs 0.5%; P =.69) were low for both stent groups. Consistent with these findings in all patients with acute MI, outcomes for the 2 DES were favorable and similar in both, with 370 patients with ST-segment elevation MI (TVF: 5.1% vs 4.9%; P =.81) and 447 patients with non—ST-segment elevation MI (TVF: 9.0% vs 7.5%; P =.56). Conclusions Resolute Integrity and Promus Element stents were both safe and efficacious in treating patients with acute MI. The present 2-year follow-up data underline the safety of using these devices in this particular clinical setting. Full English text available from: www.revespcardiol.org/en