Lower 5-year cup re-revision rate for dual mobility cups compared with unipolar cups: report of 15,922 cup revision cases in the Dutch Arthroplasty Register (2007–2016)

Background and purpose — During revision hip arthroplasty the dual mobility cup (DMC) is widely used to prevent dislocation despite limited knowledge of implant longevity. We determined the 5-year cup re-revision rates of DMC compared with unipolar cups (UC) following cup revisions in the Netherlands. Patients and methods — 17,870 cup revisions (index cup revision) were registered in the Dutch Arthroplasty Register during 2007–2016. Due to missing data 1,948 revisions were excluded and the remaining 15,922 were divided into 2 groups: DMC (n = 4,637) and UC (n = 11,285). Crude competing risk an... Mehr ...

Verfasser: Esther M Bloemheuvel
Liza N van Steenbergen
Bart A Swierstra
Dokumenttyp: Artikel
Erscheinungsdatum: 2019
Reihe/Periodikum: Acta Orthopaedica, Vol 90, Iss 4, Pp 338-341 (2019)
Verlag/Hrsg.: Medical Journals Sweden
Schlagwörter: Orthopedic surgery / RD701-811
Sprache: Englisch
Permalink: https://search.fid-benelux.de/Record/base-27016764
Datenquelle: BASE; Originalkatalog
Powered By: BASE
Link(s) : https://doi.org/10.1080/17453674.2019.1617560