Transcatheter left atrial appendage occlusion for stroke prevention in patients with atrial fibrillation: results from the Belgian registry.

This study aimed to assess the safety and efficacy at midterm follow-up of left atrial appendage occlusion (LAAO) using different devices, in real life in Belgium. Between June 2009 and November 2016, 457 consecutive patients (63% male, 75±12 yrs, CHA2DS2-VASc 4±0.6, HAS-BLED 3.5±0.7) undergoing LAAO were included. Technical success was 97.1%. There were 19 periprocedural major adverse events (4.1%) including three deaths (0.6%), nine tamponades (1.9%), four major bleedings (0.8%) and two device embolisations (0.4%). Among patients successfully implanted having a complete follow-up (672 pat... Mehr ...

Verfasser: Kefer, Joelle
Aminian, Adel
Vermeersch, Paul
de Potter, Tom
Stammen, Francis
Benit, Edouard
Budts, Werner
Missault, Luc
Drieghe, Benny
Buysschaert, Ian
Cornelis, Kristoff
Herzet, Jean-Manuel
Guedes, Antoine
Debbas, Nadia
Rivero, Maximo
Lempereur, Mathieu
Lochy, Stijn
Casado-Arroyo, Ruben
Laruelle, Christophe
Debruyne, Philippe
Ledent, Thierry
Dokumenttyp: Artikel
Erscheinungsdatum: 2018
Schlagwörter: Aged / 80 and over / Atrial Appendage / Atrial Fibrillation / Belgium / Cardiac Catheterization / Echocardiography / Transesophageal / Female / Humans / Male / Middle Aged / Registries / Risk Factors / Stroke / Time Factors / Treatment Outcome
Sprache: Englisch
Permalink: https://search.fid-benelux.de/Record/base-26915524
Datenquelle: BASE; Originalkatalog
Powered By: BASE
Link(s) : http://hdl.handle.net/2078.1/261212

This study aimed to assess the safety and efficacy at midterm follow-up of left atrial appendage occlusion (LAAO) using different devices, in real life in Belgium. Between June 2009 and November 2016, 457 consecutive patients (63% male, 75±12 yrs, CHA2DS2-VASc 4±0.6, HAS-BLED 3.5±0.7) undergoing LAAO were included. Technical success was 97.1%. There were 19 periprocedural major adverse events (4.1%) including three deaths (0.6%), nine tamponades (1.9%), four major bleedings (0.8%) and two device embolisations (0.4%). Among patients successfully implanted having a complete follow-up (672 patient-years, median follow-up 370 days), the actual annual stroke rate was 1.2%, lower than the expected stroke risk of 4% (70% reduction). The observed bleeding rate was 2%, while the calculated risk was 3.7% (46% reduction). Kaplan-Meier analysis showed a similar overall survival (93±2% and 87±3% versus 91±3% and 87±4%; p=0.35) and event-free survival (92±2% and 84±3% versus 88±3% and 80±5%; p=0.17) at one and two years, for the ACP/Amulet versus the WATCHMAN groups of patients, respectively. The data from the Belgian left atrial appendage occlusion registry suggest that the procedure is effective and relatively safe in a real-world setting, using either the WATCHMAN or the ACP/Amulet device.