Ten Years of Personnel Neutron Dosimetry with Albedo Dosemeters in the Netherlands
Since 1987, the dosimetry service of the Netherlands Energy Research Foundation has been certified by the Dutch government to perform personal dosimetry, using thermoluminescence dosemeters (TLDs). Performing neutron personal dosimetry requires a rather large investment in readers, TLDs and personnel to operate the service. About 800 persons are subjected to routine neutron monitoring in the Netherlands and their annual neutron doses are a relatively small fraction (less than 10%) of the annual H p (10). In general, the measured neutron dose values are low (on average 93% of the users receive... Mehr ...