The 2010s in clinical drug-eluting stent and bioresorbable scaffold research: a Dutch perspective

Abstract Dutch researchers were among the first to perform clinical studies in bare metal coronary stents, the use of which was initially limited by a high incidence of in-stent restenosis. This problem was greatly solved by the introduction of drug-eluting stents (DES). Nevertheless, enthusiasm about first-generation DES was subdued by discussions about a higher risk of very-late stent thrombosis and mortality, which stimulated the development, refinement, and rapid adoption of new DES with more biocompatible durable polymer coatings, biodegradable polymer coatings, or no coating at all. In t... Mehr ...

Verfasser: Kawashima, H.
Zocca, P.
Buiten, R. A.
Smits, P. C.
Onuma, Y.
Wykrzykowska, J. J.
de Winter, R. J.
von Birgelen, C.
Serruys, P. W.
Dokumenttyp: Artikel
Erscheinungsdatum: 2020
Reihe/Periodikum: Netherlands Heart Journal ; volume 28, issue S1, page 78-87 ; ISSN 1568-5888 1876-6250
Verlag/Hrsg.: Springer Science and Business Media LLC
Schlagwörter: Cardiology and Cardiovascular Medicine
Sprache: Englisch
Permalink: https://search.fid-benelux.de/Record/base-26681850
Datenquelle: BASE; Originalkatalog
Powered By: BASE
Link(s) : http://dx.doi.org/10.1007/s12471-020-01442-w

Abstract Dutch researchers were among the first to perform clinical studies in bare metal coronary stents, the use of which was initially limited by a high incidence of in-stent restenosis. This problem was greatly solved by the introduction of drug-eluting stents (DES). Nevertheless, enthusiasm about first-generation DES was subdued by discussions about a higher risk of very-late stent thrombosis and mortality, which stimulated the development, refinement, and rapid adoption of new DES with more biocompatible durable polymer coatings, biodegradable polymer coatings, or no coating at all. In terms of clinical DES research, the 2010s were characterised by numerous large-scale randomised trials in all-comers and patients with minimal exclusion criteria. Bioresorbable scaffolds (BRS) were developed and investigated. The Igaki-Tamai scaffold without drug elution was clinically tested in the Netherlands in 1999, followed by an everolimus-eluting BRS (Absorb) which showed favourable imaging and clinical results. Afterwards, multiple clinical trials comparing Absorb and its metallic counterpart were performed, revealing an increased rate of scaffold thrombosis during follow-up. Based on these studies, the commercialisation of the device was subsequently halted. Novel technologies are being developed to overcome shortcomings of first-generation BRS. In this narrative review, we look back on numerous devices and on the DES and BRS trials reported by Dutch researchers.