Long-Term Infiltration Performance Evaluation of Dutch Permeable Pavements Using the Full-Scale Infiltration Method

This research used a newly developed, full-scale infiltration testing (FSIT) procedure to determine the saturated surface infiltration rate of 16 existing permeable pavement installations in the Netherlands that have been in service for a number of years. Newly installed permeable pavements in the Netherlands must demonstrate a minimum infiltration capacity of 194 mm/h (540 L/s/ha). Only four of the 16 pavements tested in this study had an infiltration capacity higher than 194 mm/h. Most previous research has focused on unsaturated infiltration rates. However, the results of this study show th... Mehr ...

Verfasser: Floris Boogaard
Terry Lucke
Dokumenttyp: Artikel
Erscheinungsdatum: 2019
Reihe/Periodikum: Water, Vol 11, Iss 2, p 320 (2019)
Verlag/Hrsg.: MDPI AG
Schlagwörter: permeable pavement / infiltration rate / clogging / full-scale test method / monitoring / Hydraulic engineering / TC1-978 / Water supply for domestic and industrial purposes / TD201-500