Potential of an age adjusted D-dimer cut-off value to improve the exclusion of pulmonary embolism in older patients: A retrospective analysis of three large cohorts

Objectives: In older patients, the the D-dimer test for pulmonary embolism has reduced specificity and is therefore less useful. In this study a new, age dependent cut-off value for the test was devised and its usefulness with older patients assessed. Design: Retrospective multicentre cohort study. Setting: General and teaching hospitals in Belgium, France, the Netherlands, and Switzerland. Patients: 5132 consecutive patients with clinically suspected pulmonary embolism. Intervention: Development of a new D-dimer cut-off point in patients aged >50 years in a derivation set (data from two mu... Mehr ...

Verfasser: Douma, Renée A.
Le Gal, Grégoire
Söhne, Maaike
Righini, Marc
Kamphuisen, Pieter W.
Perrier, Arnaud
Kruip, Marieke J. H. A.
Bounameaux, Henri
Büller, Harry R.
Roy, Pierre-Marie
Dokumenttyp: Artikel
Erscheinungsdatum: 2010
Reihe/Periodikum: Douma , R A , Le Gal , G , Söhne , M , Righini , M , Kamphuisen , P W , Perrier , A , Kruip , M J H A , Bounameaux , H , Büller , H R & Roy , P-M 2010 , ' Potential of an age adjusted D-dimer cut-off value to improve the exclusion of pulmonary embolism in older patients: A retrospective analysis of three large cohorts ' , British Medical Journal , vol. 340 , no. 7753 , c1475 , pp. 962 . https://doi.org/10.1136/bmj.c1475
Schlagwörter: D dimer / adult / aged / article / Belgium / cohort analysis / comparative study / controlled study / diagnostic value / false negative result / female / France / human / lung embolism / major clinical study / male / Netherlands / priority journal / receiver operating characteristic / retrospective study / Switzerland / validity
Sprache: Englisch
Permalink: https://search.fid-benelux.de/Record/base-26587735
Datenquelle: BASE; Originalkatalog
Powered By: BASE
Link(s) : https://hdl.handle.net/11370/7584d1de-63fd-4f29-b232-24d1b3a3c11c

Objectives: In older patients, the the D-dimer test for pulmonary embolism has reduced specificity and is therefore less useful. In this study a new, age dependent cut-off value for the test was devised and its usefulness with older patients assessed. Design: Retrospective multicentre cohort study. Setting: General and teaching hospitals in Belgium, France, the Netherlands, and Switzerland. Patients: 5132 consecutive patients with clinically suspected pulmonary embolism. Intervention: Development of a new D-dimer cut-off point in patients aged >50 years in a derivation set (data from two multicentre cohort studies), based on receiver operating characteristics (ROC) curves. This cut-off value was then validated with two independent validation datasets. Main outcome measures: The proportion of patients in the validation cohorts with a negative D-dimer test, the proportion in whom pulmonary embolism could be excluded, and the false negative rates. Results: The new D-dimer cut-off value was defined as (patient's agex10) μg/l in patients aged 70 years, ranging from 13% to 16% in the three datasets. The failure rates (all ages) were 0.2% (95% CI0%to 1.0%) in the derivation set and 0.6% (0.3% to 1.3%) and 0.3% (0.1% to 1.1%) in the two validation sets. Conclusions: The age adjusted D-dimer cut-off point, combined with clinical probability, greatly increased the proportion of older patients in whom pulmonary embolism could be safely excluded.