ATP measurement as an objective method to measure environmental contamination in 9 hospitals in the Dutch/Belgian border area

Abstract Background The objective of this study was to determine the level of environmental contamination in hospitals in the Dutch/Belgian border area, using ATP measurements. Design A cross-sectional observational survey. Methods Standardized ATP measurements were conducted in 9 hospitals on 32 hospital wards. Thirty pre-defined surfaces per hospital ward were measured with the 3 M Clean Trace NG luminometer. Results are displayed in relative light units (RLU). RLU > 1000 was considered as “not clean.” Differences in RLU values were compared between countries, hospitals, fomite groups and... Mehr ...

Verfasser: van Arkel, Andreas
Willemsen, Ina
Kilsdonk-Bode, Linda
Vlamings-Wagenaars, Sindy
van Oudheusden, Anne
Waegemaeker, Pascal De
Leroux-Roels, Isabel
Verelst, Martine
Maas, Evelien
van Oosten, Anita
Willemse, Patricia
van Asselen, Esther
Klomp-Berens, Ella
Franssen, Karen
Van Cauwenberg, Elise
Kluytmans, Jan
Dokumenttyp: Artikel
Erscheinungsdatum: 2020
Reihe/Periodikum: Antimicrobial Resistance & Infection Control ; volume 9, issue 1 ; ISSN 2047-2994
Verlag/Hrsg.: Springer Science and Business Media LLC
Schlagwörter: Pharmacology (medical) / Infectious Diseases / Microbiology (medical) / Public Health / Environmental and Occupational Health
Sprache: Englisch
Permalink: https://search.fid-benelux.de/Record/base-26508015
Datenquelle: BASE; Originalkatalog
Powered By: BASE
Link(s) : http://dx.doi.org/10.1186/s13756-020-00730-9

Abstract Background The objective of this study was to determine the level of environmental contamination in hospitals in the Dutch/Belgian border area, using ATP measurements. Design A cross-sectional observational survey. Methods Standardized ATP measurements were conducted in 9 hospitals on 32 hospital wards. Thirty pre-defined surfaces per hospital ward were measured with the 3 M Clean Trace NG luminometer. Results are displayed in relative light units (RLU). RLU > 1000 was considered as “not clean.” Differences in RLU values were compared between countries, hospitals, fomite groups and medical specialties. Results A total of 960 ATP measurements were performed, ranging from 60 up to 120 per hospital. The median RLU-value was 568 (range: 3–277,586) and 37.7% of the measurements were rated as not clean (RLU > 1000). There were significant differences between countries, hospitals and fomite groups. Conclusion ATP measurements can be used as a more objective approach to determine the level of environmental contamination in hospitals. Significant differences in ATP levels were found between hospitals and between countries. Also, substantial differences were found between different fomite groups. These findings offer potential targets for improvement of cleanliness in healthcare facilities.