Implementation of the Infection Risk Scan (IRIS) in nine hospitals in the Belgian-Dutch border region (i-4-1-Health project)

Abstract Background A tool, the Infection Risk Scan has been developed to measure the quality of infection control and antimicrobial use. This tool measures various patient-, ward- and care-related variables in a standardized way. We describe the implementation of this tool in nine hospitals in the Dutch/Belgian border area and the obtained results. Methods The IRIS consists of a set of objective and reproducible measurements: patient comorbidities, (appropriate) use of indwelling medical devices, (appropriate) use of antimicrobial therapy, rectal carriage of Extended-spectrum beta-lactamase p... Mehr ...

Verfasser: Martine Verelst
Ina Willemsen
Veronica Weterings
Pascal De Waegemaeker
Isabelle Leroux-Roels
Ellen Nieuwkoop
Veroniek Saegeman
Lieke van Alphen
Stefanie van Kleef-van Koeveringe
Marjolein Kluytmans-van den Bergh
Jan Kluytmans
Annette Schuermans
the i-4-1-Health study group
Dokumenttyp: Artikel
Erscheinungsdatum: 2022
Reihe/Periodikum: Antimicrobial Resistance and Infection Control, Vol 11, Iss 1, Pp 1-15 (2022)
Verlag/Hrsg.: BMC
Schlagwörter: Infection prevention / Guidelines / Benchmarking / Surveillance / Infectious and parasitic diseases / RC109-216
Sprache: Englisch
Permalink: https://search.fid-benelux.de/Record/base-26500672
Datenquelle: BASE; Originalkatalog
Powered By: BASE
Link(s) : https://doi.org/10.1186/s13756-022-01083-1

Abstract Background A tool, the Infection Risk Scan has been developed to measure the quality of infection control and antimicrobial use. This tool measures various patient-, ward- and care-related variables in a standardized way. We describe the implementation of this tool in nine hospitals in the Dutch/Belgian border area and the obtained results. Methods The IRIS consists of a set of objective and reproducible measurements: patient comorbidities, (appropriate) use of indwelling medical devices, (appropriate) use of antimicrobial therapy, rectal carriage of Extended-spectrum beta-lactamase producing Enterobacterales and their clonal relatedness, environmental contamination, hand hygiene performance, personal hygiene of health care workers and presence of infection prevention preconditions. The Infection Risk Scan was implemented by an expert team. In each setting, local infection control practitioners were trained to achieve a standardized implementation of the tool and an unambiguous assessment of data. Results The IRIS was implemented in 34 wards in six Dutch and three Belgian hospitals. The tool provided ward specific results and revealed differences between wards and countries. There were significant differences in the prevalence of ESBL-E carriage between countries (Belgium: 15% versus The Netherlands: 9.6%), environmental contamination (median adenosine triphosphate (ATP) level Belgium: 431 versus median ATP level The Netherlands: 793) and calculated hand hygiene actions based on alcohol based handrub consumption (Belgium: 12.5/day versus The Netherlands: 6.3/day) were found. Conclusion The Infection risk Scan was successfully implemented in multiple hospitals in a large cross-border project and provided data that made the quality of infection control and antimicrobial use more transparent. The observed differences provide potential targets for improvement of the quality of care.